CDPMY - 302C910, CATHA-COAT 302 REINFORCED INORGANIC(SUP DAT)

  • MSDS: CDPMY
  • Manufacturer: DEVOE COATINGS CO
  • Product Name: 302C910, CATHA-COAT 302 REINFORCED INORGANIC(SUP DAT)
  • National Stock Number: 8010-00N035216
Product Identification

Product ID:302C910, CATHA-COAT 302 REINFORCED INORGANIC(SUP DAT)
MSDS Date:09/19/1995
FSC:8010
NIIN:00N035216
MSDS Number: CDPMY

Responsible Party
DEVOE COATINGS CO
4000 DUPONT CIRCLE
LOUISVILLE, KY 40207
US

Emergency Phone: 800-424-9300 (CHEMTREC)

Info Phone: 502-897-9861

Cage: 1HK86

Contractor
DEVOE COATINGS CO
7600 LOUISVILLE, KY 40207-4802 US

Telephone: 502-897-9861

Cage: 1HK86

Ingredients

TRANSFER CONTENTS TO BOTTLES/OTHER UNLABELLED

RTECS: 9999999ZZ


OF A 2 COMPONENT PROD, THEN MIX OF BASE & CONVERTER

RTECS: 9999999ZZ


OBSERVE ALL APPLICABLE PRECAUTIONS.

RTECS: 9999999ZZ


CHEM/MECH FILTER DESIGNED TO REMOVE COMBINATION

RTECS: 9999999ZZ


WEAR NIOSH APPRVD AIR SUPP RESPS/USE HOODS. USE

RTECS: 9999999ZZ


AND SANDING MATERIAL COATED WITH THIS PRODUCT.

RTECS: 9999999ZZ


HLTH STDS IN MIXING, APPLICATION & CURING AREAS & TO

RTECS: 9999999ZZ


PRODS DURING WELDING & FLAME CUTTING ON SURFS

RTECS: 9999999ZZ


BUILD-UP BY REMOVING HEAVY SOLV VAPS FROM LOWER

RTECS: 9999999ZZ


2.14; LD50 (ORAL

CAS: 110-43-0

RTECS: MJ5075000

Fraction By Weight: 10%

OSHA PEL 100 PPM

ACGIH TLV: 50 PPM


MODIFIED ALIPHATIC AMINE EPOXY HARDENER; (MODIFIED

Fraction By Weight: 5%

OSHA PEL N/K

ACGIH TLV: N/K


4.2; LD50 (ORAL RAT)

CAS: 71-36-3

RTECS: EO1400000

Fraction By Weight: 30%

OSHA PEL 100 PPM

ACGIH TLV: C 50 PPM, S

EPA Report Quantity: 5000 LBS

DOT Report Quantity: 5000 LBS


8

CAS: 68082-29-1

Fraction By Weight: 20%

OSHA PEL N/K

ACGIH TLV: N/K


> 5 G/KG

CAS: 1330-20-7

RTECS: ZE2100000

Fraction By Weight: 35%

OSHA PEL 100 PPM

ACGIH TLV: 100 PPM/150STEL

EPA Report Quantity: 1000 LBS

DOT Report Quantity: 1000 LBS


TOLUENE (SARA 313) (CERCLA)

CAS: 108-88-3

RTECS: XS5250000

OSHA PEL 200 PPM

ACGIH TLV: 50 PPM, S

EPA Report Quantity: 1000 LBS

DOT Report Quantity: 1000 LBS


654.87 G/L (CALCULATED)

RTECS: 9999999VO

OSHA PEL N/K

ACGIH TLV: N/K


(EVEN EMPTY) AS PROD/ITS RESIDUE MAY IGNITE.

RTECS: 9999999ZZ


HEALTH HAZARD. SYMPTOMS MAY NOT BE IMMEDIATELY

RTECS: 9999999ZZ


PROFESSIONALS CONCERNING LATEST HAZARD

RTECS: 9999999ZZ


ASPIRATION OF VOMITUS CAN CAUSE CHEMICAL

RTECS: 9999999ZZ


ABSORBENT AND NON-SPARKING TOOLS. STORE IN

RTECS: 9999999ZZ


PVNT BUILD-UP OF VAPS BY MAINTAINING CONTINUOUS

RTECS: 9999999ZZ


OPEN FLAME. STORE LGE QTYS IN BLDGS TO COMPLY

RTECS: 9999999ZZ

Hazards

LD50 LC50 Mixture:SEE INGREDIENTS.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:ACUTE: INHAL: IRRIT OF RESP TRACT;
HDCH, NAUS, DIZZ, WEAK & FATG. EXTREME EXPOS CAN RSLT IN UNCON &
EVEN RESP ARREST. SKIN/EYE: IRRIT. MAY BE HARMFUL IF ABSORBED THRU
SKIN. INGEST: CAN CAUSE STOM &/IN TESTINAL IRRIT, NAUS, VOMIT &
DIARR. CHRONIC: RPTS HAVE ASSOC RPTD & PRLNG OCCUP OVEREXP TO SOLVS
(EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT.
Effects of Overexposure:HLTH HAZ: W/PERM BRAIN & NERV SYS DMG.
PRLNG/RPTD BRTHG OF SPRAY MIST &/SANDING DUST OVER A PERIOD OF YRS
MAY CAUSE DUST DISEASE OF LUNGS. INTENTIONAL MISUSE BY DELIBERATELY
CONC & INHALING CONTENTS M AY BE HARMFUL/FATAL. TOLUENE APPEARS
ONTHE NAVY OCCUP CHEM REPRO HAZ LIST. SEEK CONSULT FROM APPROP HLTH
(ING 10)
Medical Cond Aggravated by Exposure:NONE, WHEN USED IN ACCORDANCE WITH
SAFE HANDLING AND USE INFORMATION.

First Aid

First Aid:INHAL: IF DFCLTY IN BRTHG, OBTAIN FRESH AIR. IF CONTINUED
DFCLTY, SUMMON MED ASSIST IMMED. IF BRTHG CEASES, RESTORE USING
APPRVD CPR TECHNIQUES & SUMMON MED HELP IMMED. EYES: FLUSH IMMED
W/LGE AMTS OF WATER FOR AT LEAST 15 MIN. GET MED ASSIST. SKIN:
WASH W/SOAP & WATER. REMOVE SOILED CLTHG. GET MED ASSIST IF IRRIT
PERSISTS. INGEST: CONSULT MD IMMED. DO NOT INDUCE VOMIT. (ING 11)

Fire Fighting

Flash Point Method:SCC
Flash Point:80.0F,26.7C
Lower Limits:0.8%
Extinguishing Media:USE CARBON DIOXIDE, DRY CHEMICAL, FOAM OR OTHER
NFPA APPROVED METHOD FOR TREATING A CLASS B FIRE.
Fire Fighting Procedures:WEAR NIOSH APPRVD SCBA & FULL PROT EQUIP .
SUMMON PROFESSIONAL FIREFIGHTERS. WATER SPRAY MAY BE INEFFECTIVE.
IF WATER IS USED, FOG NOZZ PREF. (SUP DAT)
Unusual Fire/Explosion Hazard:KEEP CONTRS TIGHTLY CLSD. ISOLATE FROM
HEAT, ELEC EQUIP, SPKS & FLAME. VAPS MAY CAUSE FLASH FIRE, IGNITE
EXPLO & SPREAD LONG DISTS & BEYOND CLSD DOORS.(SUP DAT)

Accidental Release

Spill Release Procedures:REMOVE ALL SOURCES OF IGNIT (FLAMES, HOT
SURFS, & ELEC, STATIC/FRICTIONAL SPKS). PVNT BRTHG OF VAPS. VENT
AREA. BEFORE ATTEMPTING CLEAN-UP, REFER TO HAZ CAUTION INFO IN
OTHER SECTIONS OF THIS MSDS. CO NTAIN SPILLED MATL & REMOVE W/INERT
(ING 12)
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:DO NOT BREATHE VAPS, SPRAY
MIST/SANDING DUST. DO NOT GET ON SKIN/IN EYES. KEEP AWAY FROM HEAT,
SPKS & FLAMES. DO NOT SMOKE.
Other Precautions:EXTING ALL PILOT LIGHTS & TURN OFF ALL SOURCES OF
IGNIT INCL HEATERS, FANS & OTHER NON-EXPLO-PROOF ELEC EQUIP, DURING
USE & UNTIL ALL VAPS ARE GONE. VAPS MAY IGNITE EXPLO. VAPS MAY
SPREAD LONG DISTS & BEYOND CLSD DOORS. (ING 13)

Exposure Controls

Respiratory Protection:WHEN SPRAY APPLIED IN OUTDOOR/OPEN AREAS, &
DURING SANDING/GRINDING OPERATIONS, USE NIOSH APPRVD MECH FILTER
RESP TO REMOVE SOLID AIRBORNE PARTICLES OF OVERSPRAY & SANDING
DUST. WHEN USED IN RESTRICTE D VENT AREAS, WEAR NIOSH APPRVD (ING
18)
Ventilation:PROVIDE GEN DILUTION/LOC EXHST VENT IN VOL & PATTERN TO
KEEP AIR CONTAMINANT CONC BELOW CURRENT APPLIC SFTY & (ING 21)
Protective Gloves:SOLVENT IMPERMEABLE GLOVES RECOMMENDED.
Eye Protection:ANSI APPRVD CHEM WORKERS GOGGLES .
Other Protective Equipment:ANSI APPRVD EMER EYEWASH & DELUGE SHOWER .
SOLV IMPERMEABLE CLTHG & BOOTS TO PVNT SKIN CONT ARE RECOMMENDED.
Work Hygienic Practices:REMOVE AND WASH SOILED CLOTHING BEFORE REUSE.
WASH HANDS THOROUGHLY BEFORE EATING OR SMOKING.
Supplemental Safety and Health
TRADE NAME/PART #: ZINC PRIMER COAT CONVERTER. FIRE FIGHT PROC: IF
EXPOSED TO FIRE/EXTREME HEAT, WATER SHOULD BE USED TO COOL CLSD
CONTRS & PVNT PRESS BUILD UP/POSS AUTO-IGNIT. EXPLO HAZ: DUE TO
PRESS BUILD UP, CLSD CONTRS EXPOSED TO EXTREME HEAT MAY EXPLODE.
NEVER USE WELDING/CUTTING TORCH ON/NEAR CONTR (ING 8)

Chemical Properties

Boiling Pt:B.P. Text:>244F,>118C
Vapor Pres:SEE INGS
Vapor Density:HVR/AIR
Evaporation Rate & Reference:SLOWER THAN ETHER
Appearance and Odor:NONE SPECIFIED BY MANUFACTURER
Percent Volatiles by Volume:78.44

Stability

Stability Indicator/Materials to Avoid:YES
AVOID CONTACT WITH STRONG OXIDIZING AGENTS.
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products:MAY CAUSE TOXIC FUMES WHEN HEATED TO
DECOMPOSITION. FUMES MAY CONTAIN CARBON MONOXIDE, CARBON DIOXIDE.

Disposal

Waste Disposal Methods:DISPOSE OF IN ACCORDANCE WITH LOCAL, STATE AND
FEDERAL REGULATIONS. INCINERATE ONLY IN APPROVED FACILITY. DO NOT
INCINERATE CLOSED CONTAINERS.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.